EDI COSTORContainer stuffing stripping order message

Transaction set

This specification provides the definition of the container stuffing/stripping order message (costor) to be used in electronic data interchange (edi) between trading partners involved in administration, commerce and transport.

Segments

Position
Segment
Name
Max use
10
UNH
Message header
To end and check the completeness of an interchange
Mandatory
AtMax 1
20
BGM
Beginning of message
To indicate the type and function of a message and to transmit the identifying number.
Mandatory
AtMax 1
30
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
40
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
1LOOPOpt
AtMax 9
60
RFF
Reference
To specify a reference.
Mandatory
AtMax 1
70
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
2LOOPMandatory
AtMax 1
90
TDT
Details of transport
To specify the transport details such as mode of transport, means of transport, its conveyance reference number and the identification of the means of transport. the segment may be pointed to by the tpl segment.
Mandatory
AtMax 1
100
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
3LOOPOpt
AtMax 9
120
LOC
Place/location identification
To identify a place or a location and/or related locations.
Mandatory
AtMax 1
130
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
4LOOPMandatory
AtMax 9
150
NAD
Name and address
To specify the name/address and their related function, either by c082 only and/or unstructured by c058 or structured by c080 thru 3207.
Mandatory
AtMax 1
5LOOPOpt
AtMax 9
170
CTA
Contact information
To identify a person or a department to whom communication should be directed.
Mandatory
AtMax 1
180
COM
Communication contact
To identify a communication number of a department or a person to whom communication should be directed.
Opt
AtMax 9
6LOOPMandatory
AtMax 999
200
EQD
Equipment details
To identify a unit of equipment.
Mandatory
AtMax 1
210
RFF
Reference
To specify a reference.
Opt
AtMax 9
220
EQN
Number of units
To specify the number of units.
Opt
AtMax 1
230
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
240
TSR
Transport service requirements
To specify the contract and carriage conditions and service and priority requirements for the transport.
Opt
AtMax 9
250
LOC
Place/location identification
To identify a place or a location and/or related locations.
Opt
AtMax 9
260
DIM
Dimensions
To specify dimensions.
Opt
AtMax 9
270
HAN
Handling instructions
To specify handling and where necessary, notify hazards.
Opt
AtMax 9
7LOOPOpt
AtMax 9
290
NAD
Name and address
To specify the name/address and their related function, either by c082 only and/or unstructured by c058 or structured by c080 thru 3207.
Mandatory
AtMax 1
300
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
8LOOPOpt
AtMax 99
320
DGS
Dangerous goods
To identify dangerous goods.
Mandatory
AtMax 1
330
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
340
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
9LOOPOpt
AtMax 9
360
CTA
Contact information
To identify a person or a department to whom communication should be directed.
Mandatory
AtMax 1
370
COM
Communication contact
To identify a communication number of a department or a person to whom communication should be directed.
Opt
AtMax 9
10LOOPOpt
AtMax 9
390
TMP
Temperature
To specify the temperature setting.
Mandatory
AtMax 1
400
RNG
Range details
To identify a range.
Opt
AtMax 1
11LOOPMandatory
AtMax 999
420
CNI
Consignment information
To identify one consignment.
Mandatory
AtMax 1
430
RFF
Reference
To specify a reference.
Opt
AtMax 9
440
NAD
Name and address
To specify the name/address and their related function, either by c082 only and/or unstructured by c058 or structured by c080 thru 3207.
Opt
AtMax 9
12LOOPOpt
AtMax 999
460
GID
Goods item details
To indicate totals of a goods item.
Mandatory
AtMax 1
470
HAN
Handling instructions
To specify handling and where necessary, notify hazards.
Opt
AtMax 9
13LOOPOpt
AtMax 9
490
TMP
Temperature
To specify the temperature setting.
Mandatory
AtMax 1
500
RNG
Range details
To identify a range.
Opt
AtMax 1
510
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
520
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
14LOOPOpt
AtMax 9
540
NAD
Name and address
To specify the name/address and their related function, either by c082 only and/or unstructured by c058 or structured by c080 thru 3207.
Mandatory
AtMax 1
550
DTM
Date/time/period
To specify date, and/or time, or period.
Opt
AtMax 9
560
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
570
PCI
Package identification
To specify markings and labels on individual packages or physical units.
Opt
AtMax 9
580
DOC
Document/message details
To identify documents and details directly related to it.
Opt
AtMax 9
15LOOPOpt
AtMax 999
600
SGP
Split goods placement
To specify the placement of goods in relation to equipment.
Mandatory
AtMax 1
610
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
16LOOPOpt
AtMax 99
630
DGS
Dangerous goods
To identify dangerous goods.
Mandatory
AtMax 1
640
FTX
Free text
To provide free form or coded text information.
Opt
AtMax 9
650
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
17LOOPOpt
AtMax 9
670
CTA
Contact information
To identify a person or a department to whom communication should be directed.
Mandatory
AtMax 1
680
COM
Communication contact
To identify a communication number of a department or a person to whom communication should be directed.
Opt
AtMax 9
18LOOPOpt
AtMax 999
700
SGP
Split goods placement
To specify the placement of goods in relation to equipment.
Mandatory
AtMax 1
710
MEA
Measurements
To specify physical measurements, including dimension tolerances, weights and counts.
Opt
AtMax 9
720
CNT
Control total
To provide control total.
Opt
AtMax 1
730
UNT
Message trailer
To end and check the completeness of a message.
Mandatory
AtMax 1

Elements

PositionElementNameRequirementTypeMin/MaxRepeat
10
Message reference numberMandatoryAlphanumeric1/1AtMax 1
20
Message identifierMandatoryAtMax 1
10
Message type identifierMandatoryAlphanumeric1/1Exact 1
20
Message type version numberMandatoryAlphanumeric1/1Exact 1
30
Message type release numberMandatoryAlphanumeric1/1Exact 1
40
Controlling agencyMandatoryAlphanumeric1/1Exact 1
50
Association assigned codeOptAlphanumeric1/1Exact 1
30
Common access referenceOptAlphanumeric1/1AtMax 1
40
Status of the transferOptAtMax 1